| Introduction and Forward Link Power Control By Dr. Ernest Simo
38.0 How are Frame Error Rate Statistics reported to the Base Station?
Frame Error Rates are reported to the Base Station in the following manner:
Both Periodic and Threshold reporting modes may be enabled simultaneously, either one of them may be enabled, or both modes may be disabled at any given time.
- The Frame Error Rate Statistics (FER) are sent to the Base via a Power Measurement Report message (PMRM).
- After sending the PMRM to the Base, the Mobile Unit shall reset the Total-Frame counter and the Bad-Frame counter to zero, and;
- shall not increment either counter for a period of time following the first transmission of the PMRM .
- This nominal period of time is referred to as the Power Report Delay and is defined in the Power Control Parameters message.
Click here to view Figure 25

 © 2001 DR. ERNEST SIMO - SPACE2000 |